Sparksy
replied to the thread
No Options Apply
Suburban hotwater unit wont run unless door is open.
.
Thanks. But the suburban hot water doesnt use a thermocouple to hold the flame failure solenoid for gas flow. I can see your point but...
Saturday at 11:48 AM
Boots in Action
reacted to
Drover's post
in the thread
Drovers new Rig - "Big Mal"
with
Like
.
I dismantled the level indicator and other rubbish years ago, just pulled it all out and binned it, so the solenoid is all thats left...
Saturday at 9:37 AM
Boots in Action
reacted to
Sparksy's post
in the thread
Drovers new Rig - "Big Mal"
with
Like
.
After a incident where the solenoid jammed open , I fitted a isolating valve in the supply water line under the floor. On a side note ...
Saturday at 9:36 AM
Boots in Action
reacted to
Drover's post
in the thread
Drovers new Rig - "Big Mal"
with
Wow
.
Well the Flood Alarm went off today, as the tide started to lap at my feet, the flush button on Dunny had jammed, quick race outside...
Saturday at 9:36 AM
Boots in Action
replied to the thread
No Options Apply
Suburban hotwater unit wont run unless door is open.
.
I had a similar problem regarding the thermocouple with my 3 way fridge. All was fine for months and then when I was testing fridge at...
Saturday at 9:33 AM
jazzeddie1234
replied to the thread
No Options Apply
Suburban hotwater unit wont run unless door is open.
.
It could be the probes but the board has a well documented fault where the sensitivity to the flame (well the current measured as the...
Sep 9, 2025
S
Sparksy
replied to the thread
Drovers new Rig - "Big Mal"
.
After a incident where the solenoid jammed open , I fitted a isolating valve in the supply water line under the floor. On a side note ...
Sep 8, 2025
S
Sparksy
replied to the thread
No Options Apply
Suburban hotwater unit wont run unless door is open.
.
Ive cleaned the probes but if it was the board then the board would instantly switch off the gas. In this case the flame slowly looses...
Sep 8, 2025
Hitting the road
reacted to
Drover's post
in the thread
Drovers new Rig - "Big Mal"
with
Like
.
Well the Flood Alarm went off today, as the tide started to lap at my feet, the flush button on Dunny had jammed, quick race outside...
Sep 7, 2025
jazzeddie1234
reacted to
Drover's post
in the thread
Drovers new Rig - "Big Mal"
with
Like
.
Well the Flood Alarm went off today, as the tide started to lap at my feet, the flush button on Dunny had jammed, quick race outside...
Sep 6, 2025
DRW
reacted to
Drover's post
in the thread
Drovers new Rig - "Big Mal"
with
Like
.
Well the Flood Alarm went off today, as the tide started to lap at my feet, the flush button on Dunny had jammed, quick race outside...
Sep 6, 2025
jazzeddie1234
reacted to
chartrock's post
in the thread
NSW - For Sale
2004 Expanda 16.49.3 parts
with
Like
.
Sounds like it was a large but worthwhile project, @Mikedebs. Well done, and I’m sure members would love some pix of the finished product.
Sep 5, 2025
Boots in Action
reacted to
Mikedebs's post
in the thread
NSW - For Sale
2004 Expanda 16.49.3 parts
with
Like
.
Hi Chartrock. Thanks for your interest. Had been looking for a long time, but could not find an outback (off-grid) 2 person tourer...
Sep 5, 2025
Boots in Action
reacted to
jazzeddie1234's post
in the thread
No Options Apply
Suburban hotwater unit wont run unless door is open.
with
Haha
.
Twas me! The flame is supposed to create a small current flow across the probes that is detected by the circuit board and that holds...
Sep 5, 2025
jazzeddie1234